70 cm 430 – 440 MHz 2.5 kW -0.06 dB Transmitting Band Pass Filter
With its extreme low insertion loss this filter could be used as transmitting and receiving filter in line with antenna.
– As transmitting to suppress any harmonics from 70 cm up to 2.5 kW linear amplifiers.
– On receive side before LNA to protect receive performance from any HF, FM 2 m, 220 MHz or 23 cm strong stations.
Filter is completely the same as 1 kW version except connectors (7/16 DIN – “N”).
Achieved results on a built Band pass filter:
Frequency [MHz] |
Insertion Loss [dB] |
1.8 MHz | -110 dB |
3.8 MHz | -110 dB |
7.1 MHz | -108 dB |
14.15 MHz | -100 dB |
21.4 MHz | -92 dB |
28.4 MHz | -84 dB |
50.1 MHz | -69 dB |
70.2 MHz | -60 dB |
88 MHz | -54 dB |
144 MHz | -39 dB |
146 MHz | -39 dB |
148 MHz | -38 dB |
220 MHz | -24 dB |
225 MHz | -23 dB |
430 MHz | -0.06 dB, Input RL batter than -34 dB |
432.1 MHz | -0.06 dB, Input RL batter than -34 dB |
440 MHz | -0.06 dB, Input RL batter than -34 dB |
860 MHz | -26 dB |
864.2 MHz | -26 dB |
880 MHz | -27 dB |
1240 Mhz | -64 dB |
1296.1 MHz | -48 dB |
Maximum Power Input at SWR: | [W] |
1 : 1 | 2500 W |
1 : 1.1.5 | 1600 W |
1 : 2 | 1350 W |
1 : 3 | 1150 W |
Measured data on the assembled filter with HP8753ES network analyzer full 2-port calibrated:
Extreme Power 70 cm Band-pass Filter 2500 W S11 and S21
70 cm Band pass Filter 2500 W HF Suppression:
432MHz Band pass Filter 2.5 kW: HF, 6m, FM Suppression:
432 MHz Band Pass Filter 2.5 kW: 2m and 1.25m Suppression:
430 – 440 MHz Band-pass Filter 2.5 kW Measured Data zoomed characteristics.
Insertion Loss is set to 0.2 dB! Excellent Band Flatness and supper low loss of BPF!
70 cm Band-pass Filter 2500 W Harmonics Suppression:
430MHz-440MHz Extra Power Band Pass Filter 2500W Fan Cooled Appearance:

All band-pass filters are here: HF, VHF and UHF Band-Pass Filters
Direct link to all 70 cm filters. 50 W, 100 W, 200 W, 300 W, 1000 W and 2500 W versions: 70 cm Band-Pass Filters
Reviews
There are no reviews yet.