The external appearance of the filter:
The recorded data on the assembled filter with HP8753ES full 2-port calibrated are presented below.
We measured Return Loss (S11) and Insertion Loss (S21). Characteristics of 50 MHz Bandpass filter for up to 300 W transmitter.
Achieved results on Band-pass Filter (Attenuation) |
||||||||||||
HF Band
|
||||||||||||
Bandwidth: 50 – 51 MHz
|
||||||||||||
FM attenuation
|
||||||||||||
144 MHz / 432 MHz Band Attenuation
|
1. Measured HF attenuation:
2. Measured FM and VHF attenuation:
3. Measured UHF attenuation: