Universal 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays for 2m, 1.25m, and 70cm Terrestrial Contesting and EME
Integrated low-noise preamplifier with powerful transmit/receive relays on all three bands. Use this 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays for any kind of terrestrial or EME communications. JT65, FT8 CW, FM, or SSB. Integrated super low loss input bandpass filter that will prevent overloading of any HF, 6m, 4m, or 23cm stations. Super low noise preamplifier will allow you to hear even the weakest signals. QRO made on Rogers RF Laminates.
This universal preamplifier is an excellent solution for any 2m antenna, dual-band 2m 70cm antenna, 1.25m antenna, and 70cm antenna
Universal 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Transmit/ Receive Relays appearance
3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays consist of:
- Super low loss input bandpass filter. The loss of filter is about 0.1dB
- Low noise preamplifier
- High Power transmit/receive relays
- By order, the Fail Safe Relay option
Receive gain on Universal 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays:
1.8 MHz –63 dB
3.8 MHz –62 dB
7.02 MHz –62 dB
14.02 MHz –59 dB
21.02 MHz –53 dB
14.02 MHz –59 dB
28.4 MHz –58 dB
50.11 MHz –28 dB
70.2 MHz –7 dB
144-148 MHz +25 dB, NF=0.6 dB, Input RL -10 dB, IP3out >37 dBm
219-225 MHz +23.8 dB, NF=0.6 dB, Input RL -15 dB, IP3out >37 dBm
430-450 MHz +20 dB, NF=0.65 dB, Input RL -12 dB, IP3out >37 dBm
720 MHz –16 dB
864 MHz –31 dB
930 MHz (GSM) –35 dB
1296 MHz –26 dB
Power consumption: + 12 V, 300 mA
Transmit delay: 100 ms
Transmit path: RL≤ -34dB, Max SWR ≤1.04, Insertion Loss ≤ 0.1dB
2m Maximum power input at SWR 1:1 1500W, 1:1.5 950W, 1:2 700W, 1:3 500W
1.25m Maximum power input at SWR 1:1 1300W, 1:1.5 1000W, 1:2 650W, 1:3 450W
70cm Maximum power input at SWR 1:1 1200W, 1:1.5 1000W, 1:2 600W, 1:3 400W
Connectors: “N” (by order: 7/16 DIN)
Outdoor version: +9 EUR
Fail-safe option: +10 EUR
Universal 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier T/R Relays Internal Schematic
With any preamplifier sequencer is mandatory. Use this schematic. Put 100 ms delay.
Measured results on universal 3Band EME2 for 2m, 1.25m, and 70cm
Universal 3Band EME2 HF Attenuation
Universal 3Band EME2 2m, 1.25m, 70cm Filter Preamplifier Relays 10m 6m 4m Attenuation
3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays Gain
Universal 3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays Harmonics 23cm Attenuation
3Band EME2 144MHz 222MHz 432MHz Filter Preamplifier Relays Transmit Side SWR
Our EME2 – EME3 family:
6m band, EME2-50
6m band, EME3-50
DualBand 6m-4m EME2-5070 (soon)
DualBand 6m-4m EME3-5070 (soon)
4m band, EME2-70
4m band, EME3-70
2m band, EME2-144
2m band, EME3-144
3Band 2m, 1.25m, and 70cm EME2 (this one)
3Band 2m, 1.25m, and 70cm EME3 (by order)
70cm band, EME2-432
70cm band, EME3-432
Reviews